Input | Operating Voltage | 198-264VAC 50Hz /60Hz |
Rated Input Voltage | 220-240VAC 50Hz /60Hz | |
DC Input Voltage range | 200-240VDC | |
Input Current | 0.12A Max. | |
Input Inrush Current | <25A (Half current pulse width 100US) @230VAC | |
Power Factor | ≥0.93 @230VAC (Full load) | |
Total harmonic distortion (@230Vac, 100% load) |
Typical: 13% | |
No-load power | ≤0.5W | |
Stand-by Power | ≤0.5W (@230Vac) | |
Efficiency (@230VAC Full load) | 83%Max. | |
Wiring Method | Push terminal, wire cross section:0.75-1.5mm² | |
Output | Operating mode | Constant Current |
Load type | LED | |
Ripple requirement (Flickering or flickering-Free) | Flicker value: less than 5% for whole dimming range | |
Start up time | <1s (@230Vac) | |
No-load output voltage | 57VDC Max. | |
Load output voltage range | 9-45VDC | |
Full load output power | 20W Max. | |
Load output current | 200-550mA | |
Constant current/voltage Precision | Constant Current Precision ±5% | |
Wiring method | Push terminal, wire cross section:0.75-1.5mm² | |
Control Method | Working frequency | 2.4-2.48GHz |
Transmitting power | +8dBm (Max.) | |
Transmission distance | <50m (Visible distance) | |
Modulation mode | O-QPSK PHY | |
Exception Protection Requirements | Output over temperature protection | Yes, without self recovery function (Can be inquired) |
Output short circuit protection | Yes, without self recovery function (Can be inquired) | |
Operating Environment | Operating temperature/ humidity | -25℃~50℃ Humidity:85% (Non-condensing) |
Storage temperature/ humidity | -40℃~80℃, Humidity:10%–95% | |
Max. case temp(Tc) | 85℃ | |
Safety & EMC | EMC standard | EN55015 EN61547 EN61000-3-2 EN61000-3-3 |
Safety standard | EN61347-1 EN61347-2-13 | |
Certification | CB, CE | |
Withstand voltage | 3750Vac, 5mA, 60s (Input “L N”- Output “SEC”) | |
Others | Degrees of protection | IP20 |
Type of protection | Class II | |
Installation type | Independent installation | |
With crimping | 116*40.5*22mm | |
Without crimping | 78*40.5*22mm | |
Packaging requirement | PE bag+white box+Instructions+Clapboard+Outer Carton(K=A) | |
Weight | 53.5±5g | |
Life | 5 year @Ta full load | |
Note: All parameters are tested at the input voltage of 230Vac and 25 degree environment unless specified. |
Matters Needing Attention
1) The LED string must be connected to the load before turning on the input power, otherwise the LED string may be damaged.
2) After the LED drive input is powered off, there will be a residual voltage at the output, which can be maintained for about 3 minutes.